4.7.4 Allowable Nozzle Loads
Discharge piping should be constructed to fit to the
ESP3 discharge piping flange. The ESP3 design
can accommodate large piping loads without
affecting the operation of the pump, but the
installation should not impose unnecessary loads to
the discharge flange. The allowable piping loads
are shown in Figure 4.2.
Figure 4-2 ESP3 Nozzle Loading
1
max
max
max
max
max
max
≤
+
+
+
+
+
Mz
Mz
My
My
Mx
Mx
Fz
Fz
Fy
Fy
Fx
Fx
Force N
Moments Nm
Group
Size
Fx
Fy
Fz
Mx
My
Mz
1E
1.5x1LFSP-4
760
1270
760
414
441
414
1E
1.5x1SP-62
760
1270
760
414
441
414
1E
3x1.5SP-62
930
1560
930
515
542
515
1E
3x2SP-62
1110
1870
1110
610
644
610
1E
1.5x1SP-8
760
1270
760
414
441
414
1E
1.5x1LFSP-8
760
1270
760
414
441
414
1E
3x1.5SP-82
930
1560
930
515
542
515
1E
3x2SP-82
1110
1870
1110
610
644
610
2E
3x1.5SP-82
930
1560
930
515
542
515
2E
3x2SP-82
1110
1870
1110
610
644
610
2E
4x3SP-82
1380
2310
1380
759
800
759
2E
2x1SP-10A
760
1270
760
414
441
414
2E
2x1LFSP-10
760
1270
760
414
441
414
2E
3x1.5SP-10
930
1560
930
515
542
515
2E
2x2RSP-10
1110
1870
1110
610
644
610
2E
3x2SP-10
1110
1870
1110
610
644
610
2E
3x3RSP-10
1380
2310
1380
759
800
759
2E
4x3SP-10
1380
2310
1380
759
800
759
2E
4x3SP-10H
1380
2310
1380
759
800
759
2E
6x4SP-10\H
1780
2980
1780
976
1030
976
2E
3x1.5SP-13
930
1560
930
515
542
515
2E
3x1.5LFSP-13
930
1560
930
515
542
515
2E
3x2SP-13
1110
1870
1110
610
644
610
2E
4x3SP-13\HH
1380
2310
1380
759
800
759
2E
4x3RSP-13
1380
2310
1380
759
800
759
3E
6x4SP-13A
1780
2980
1780
976
1030
976
3E
6x4RSP-13
1780
2980
1780
976
1030
976
3E
8x6SP-14A
2340
3890
2340
1281
1356
1281
3E
10x8SP-14
2800
4670
2800
1539
1620
1539
3E
6x4SP-16\A
1780
2980
1780
976
1030
976
3E
8x6SP-16
2340
3890
2340
1281
1356
1281
3E
10x8SP-16\H
2800
4670
2800
1539
1620
1539