beautypg.com

Faults; causes and remedies (7), Trouble-shooting (see 7) – Flowserve CPX IDP User Manual

Page 33

background image

CPX, CPXR, CPXN and CPXP USER INSTRUCTIONS ENGLISH 71569117 09-11

Page 33 of 44

flowserve.com

6.11.3 Tandem seal types

6.11.3.1

Tandem seal with Flowserve eccentric

pumping annulus circulation

BI - Rp ¼ in. barrier liquid inlet
BO - Rp ¼ in. barrier liquid outlet
F - Rp ¼ in. flush

Pump

size

Setting dimensions (mm)

Frame 1

Frame 2

Frame 3

Frame 4

X

Y

X

Y

X

Y

X

Y

125

20.0 31.5

-

-

-

-

-

-

160

20.0 31.5 28.0 41.5

-

-

-

-

200

20.0 26.5 28.0 41.5

-

-

-

-

250

-

-

28.0 36.4 27.5 33.7

-

-

315

-

-

28.0 36.4 27.5 33.7 45.5 56.7

400

-

-

-

-

27.5 25.3 45.5 48.3

500

-

-

28.0 36.4 27.5 33.7 45.5 56.7


6.11.4 Double seal types

6.11.4.1

Double back-to-back seal with Flowserve

eccentric pumping annulus circulation

Pump size

Setting dimension X (mm)

Frame 1

Frame 2

Frame 3

Frame 4

125

11.0

-

-

-

160

11.0

17.5

-

-

200

6.0

17.5

-

-

250

-

12.4

14.4

-

315

-

12.4

14.3

32.3

400

-

-

5.7

24.0

500

-

12.4

14.3

32.3

6.11.5 External seal types

6.11.5.1

External seal

D - drain


6.11.6 Packed gland seal types

6.11.6.1

Packed gland with fibre packing

4120

4130

4134

F - Rp ¼ in. flush


BI - Rp ¼ in. barrier liquid inlet
BO - Rp ¼ in. barrier liquid outlet

This manual is related to the following products: