8 disassembly, Disassembly (6.8), Dismantling (6.8, disassembly) – Flowserve CPX IDP User Manual
Page 27

CPX, CPXR, CPXN and CPXP USER INSTRUCTIONS ENGLISH 71569117 09-11
Page 27 of 44
flowserve.com
For CPX, CPXN and CPXP 
d) Tighten the bearing carrier screws [6570.2] evenly, 
drawing the bearing carrier towards the bearing 
housing, until the impeller [2200] contacts the pump 
casing. [1100] Turn the shaft [2100], during this 
procedure, until a detectable rub is obtained. This 
is the zero clearance position. 
e) Set a dial indicator to zero on the shaft end or
measure the bearing carrier to bearing housing 
gap and record the measurement. 
f) Slacken the bearing carrier screws [6570.2]. 
g) Tighten jacking screws [6570.3] evenly (about 
one flat at a time) until the dial indicator or feeler 
gauge shows the correct impeller clearance from 
the zero clearance position. This clearance 
should be between 0.3 and 2 mm (0.008 and 
0.080 in.) depending on the nature of the pumped 
fluid. (See table above.) 
h) Evenly tighten the bearing carrier screws [6570.2]
keeping the dial indicator or feeler gauges reading 
the correct setting. Then tighten the hex nuts 
[6580.1] to lock the jacking screws in position. 
 
For CPXR only 
The impeller does not have a fine front
clearance setting and adjustment of the impeller 
is not normally required. 
d) Tighten the jacking screws [6570.3] evenly, pushing
the bearing carrier away from the bearing housing, 
until the impeller [2200] contacts the cover. [1220] 
Turn the shaft [2100], during this procedure, until a 
detectable rub is obtained. This is the zero 
clearance position. 
e) Set a dial indicator to zero on the shaft end or
measure the bearing carrier to bearing housing 
gap and record the measurement. 
f) Slacken the jacking screws [6570.3]. 
g) Tighten bearing carrier screws [6570.2] evenly 
(about one flat at a time) until the dial indicator or 
feeler gauge shows the correct impeller 
clearance from the zero clearance position. This 
clearance should be 1.5 - 2 mm (0.06 - 0.08 in.) 
(See drawing.) 
h) Tighten the jacking screws [6570.3] until they
contact the bearing carrier, keeping the dial 
indicator or feeler gauges reading the correct 
setting. Then tighten the hex nuts [6580.1] to 
lock the jacking screws in position. 
 
For all pump types 
i) 
Compare the original and final gaps between the 
bearing carrier and bearing housing to check if 
the movement of the shaft has exceeded the seal 
capability (over/under compression of seal). 
Re-position the seal to correct this. 
j)
Check that the shaft [2100] can turn freely without 
binding. 
k) If a cartridge seal [4200] is fitted it should be
reset at this point.
l)
Ensure the coupling distance between shaft ends 
(DBSE) is correct. Reset/re-align if necessary. 
6.8 Disassembly
Refer to Safety section before dismantling the
pump.
Before dismantling the pump for
overhaul, ensure genuine Flowserve replacement 
parts are available. 
 
Refer to sectional drawings for part numbers and 
identification. See section 8, Parts lists and drawings. 
 
6.8.1 Bearing housing 
To remove, proceed as follows: 
a) Disconnect all auxiliary pipes and tubes where 
applicable.
b) Remove coupling guard and disconnect coupling. 
c) If oil lubricated frame, drain oil by removing drain 
plug [6569.3].
d) Record the gap between the bearing carrier and
bearing housing so that this setting can be used 
during workshop assembly. 
e) Place hoist sling through bearing housing window. 
f) Remove casing screws [6570.1] and support foot 
[3134] to baseplate screws.
g) Remove bearing housing assembly from pump
casing [1100]. The two threaded holes in the 
bearing housing flange can be used for jacking 
screws to assist with removal. 
h) Remove pump casing gasket [4590.1] and
discard. A replacement gasket will be required 
for assembly. 
i)
Clean gasket mating surfaces.
On CPXP diffuser casing sizes it is not
normally necessary to remove the diffuser [1410, 
4590.2 and 6570.5]. 