Motor size 
and speed 
kW (hp)
Typical sound pressure level L
pA
at 1 m reference 20 μPa, dBA
3 550 r/min
2 900 r/min
1 750 r/min
1 450 r/min
Pump
only
Pump and
motor
Pump
only
Pump and
motor
Pump
only
Pump and
motor
Pump
only
Pump and
motor
<0.55 (<0.75)
72
72
64
65
62
64
62
64
0.75 (1)
72
72
64
66
62
64
62
64
1.1 (1.5)
74
74
66
67
64
64
62
63
1.5 (2)
74
74
66
71
64
64
62
63
2.2 (3)
75
76
68
72
65
66
63
64
3 (4)
75
76
70
73
65
66
63
64
4 (5)
75
76
71
73
65
66
63
64
5.5 (7.5)
76
77
72
75
66
67
64
65
7.5 (10)
76
77
72
75
66
67
64
65
11 (15)
80
81
76
78
70
71
68
69
15 (20)
80
81
76
78
70
71
68
69
18.5 (25)
81
81
77
78
71
71
69
71
22 (30)
81
81
77
79
71
71
69
71
30 (40)
83
83
79
81
73
73
71
73
37 (50)
83
83
79
81
73
73
71
73
45 (60)
86
86
82
84
76
76
74
76
55 (75)
86
86
82
84
76
76
74
76
75 (100)
87
87
83
85
77
77
75
77
90 (120)
87
88
83
85
77
78
75
78
110 (150)
89
90
85
87
79
80
77
80
150 (200)
89
90
85
87
79
80
77
80
200 (270)
85
87
83
85
300 (400)
–
87
90
85
86
 The noise level of machines in this range will most likely be of values which require noise exposure control, but typical values are
inappropriate.
Note: for 1 180 and 960 r/min reduce 1 450 r/min values by 2 dBA. For 880 and 720 r/min reduce 1 450 r/min values by 3 dBA.
2
TRANSPORT AND STORAGE
2.1 Consignment receipt and unpacking
Immediately after receipt of the equipment it must be 
checked against the delivery/shipping documents for 
its completeness and that there has been no damage 
in transportation. Any shortage and/or damage must 
be reported immediately to Flowserve Solution group 
and must be received in writing within one month of 
receipt of the equipment. Later claims cannot be 
accepted. 
 
Check any crate, boxes or wrappings for any 
accessories or spare parts that may be packed 
separately with the equipment or attached to side 
walls of the box or equipment. 
 
Each product has a unique serial number. Check 
that this number corresponds with that advised and 
always quote this number in correspondence as well 
as when ordering spare parts or further accessories. 
 
2.2 Handling
Boxes, crates, pallets or cartons may be unloaded 
using fork lift vehicles or slings dependent on their 
size and construction. 
 
2.3 Lifting
A crane must be used for all pump sets in
excess of 25 kg (55 lb). Fully trained personnel must 
carry out lifting, in accordance with local regulations. 
 
Slings, ropes and other lifting gear should be 
positioned where they cannot slip and where a 
balanced lift is obtained. The angle between sling or 
ropes used for lifting must not exceede 60°. 
 
2.3.1 Bare shaft pump 
The bare shaft pump should be lifted as shown. 
Place a sling around the suction nozzle and one 
around the pump bearing housing using pulled tight 
choker hitches. 