Panasonic provides the EasyIpSetup_Ipro utility to find IP cameras. Run the utility to display the following window:
Select a camera and click the IP Setting button to view and edit the camera’s IP properties.
Panasonic cameras typically do not use DHCP by factory default, you must manually assign the camera an IP address. Enter
an IP address that is not used by any other device on your local network, ensuring that the first three numbers match the
first three numbers of your exacqVision Server’s IP address. Set the net mask to 255.255.255.0, leave the HTTP port at 80,
enter the camera’s Administrator name and password, and click Apply.
NOTE: Panasonic cameras automatically disable their response to configuration queries 20 minutes after being reset. If your
camera has been running for more than 20 minutes, reset or power cycle it before querying or configuring its IP address
through either exacqVision’s IP camera finder or Panasonic’s EasyIPSetup utility.
NOTE: The factory default login for Panasonic IP cameras is:
username: admin
password: 12345
You will need the username and password when you add this camera to your exacqVision system.