16 triton® tr6 – Electro-Chemical Devices (ECD) T80 User Manual
Page 66
Weights:
Cable length 7 m (23 ft): 0.7 kg (1.5 lbs)
Cable length 15 m (49 ft): 1.1 kg (2.4 lbs)
8.4.16
TRITON®
TR6
Measuring principle:
Particle caused back scattering of 850 nm near infrared light with sunlight rejection filter
Measuring Range:
-1 Sensor
0.0 ... 250.0 NTU, FNU & 0 ... 1000 NTU, FNU
-2 Sensor
0.0 ... 500.0 NTU, FNU & 0 ... 2000 NTU, FNU
-3 Sensor
0 ... 1000 NTU, FNU& 0 ... 4000 NTU, FNU
-4 Sensor
0 ... 2000 NTU, FNU & 0 ... 4000
NTU, FNU ppm, mg/L and %solids to equivalent NTU value
Accuracy:
2% of reading or 0.5 NTU, whichever is larger
Process Temperature Range:
–5 ... 50°C
Temperature Compensation:
Internal Temperature compensation
Process pressure range:
50 psi maximum in Flow Cell
500meter submersion depth (50 bar, 725 psi)
Vacuum operation is not permitted
Drift:
< 1% / month
Wetted Materials
Sensor body: stainless steel AISI 316 Ti
Sensing end: epoxy
Process Connection:
1” NPT Nylon compression fitting
Electrical connection
Waterproof 5-wire measuring cable or
Water Resistant 5-wire measuring cable (Standard)
Cable Length:
10ft. (3.0 m), 20ft (6.1 m), 30ft (9.1 m) cables
Page 65
Model T80