beautypg.com

DNF Controls SW32PS_Port_Switcher User Manual

Page 10

background image

Page 9 of 24

SW32PS RS422 Port Switcher

3)

Configure AMEZI card on the GV7000 for 20-TEN protocol.


4) Press

[MENU].


5)

Turn the Wheel until the display says: “Ext. Interface:”


6) Press

[TAKE] to select RS232 or RS422, depending on what interface you are

using.


7)

Turn the Wheel until the display says “Parity: ”


8) Press

[TAKE] to select ODD, EVEN or NONE to match parity on what the

AMEZI card is configured for.

9)

Turn the Wheel until the display says “BAUD RATE:”


10) Press

[TAKE] to select 9600, 19.2K or 38.4K to match baud rate on what the

AMEZI card is configured for.


11)

Turn the wheel until the display says “Protect.”

12)

Press [TAKE] to enable or disable Protecting Destinations.

13)

Turn the wheel until the display says “UNUSED LVLS:”

14)

Press [TAKE] to select sending the status of unused levels as “NOT-
Connected” or “DISABLED.”


15)

Turn the Wheel until the display says “Set STROBE.”


16) Press

[TAKE].


17)

The display shows current strobe (level) number.


18)

Turn the Wheel to select level 1-4.


19) Press

[ESC] twice to exit SETUP MENU.


Setup is complete. The GV7000 can now control the SW32PS.

NOTE: Default settings for communications are: RS422, 34.8, No parity, 8 bits data,
1 stop bit.