SW32PS RS422 Port Switcher
3)
Configure AMEZI card on the GV7000 for 20-TEN protocol.
4) Press
[MENU].
5)
Turn the Wheel until the display says: “Ext. Interface:”
6) Press
[TAKE] to select RS232 or RS422, depending on what interface you are
using.
7)
Turn the Wheel until the display says “Parity: ”
8) Press
[TAKE] to select ODD, EVEN or NONE to match parity on what the
AMEZI card is configured for.
9)
Turn the Wheel until the display says “BAUD RATE:”
10) Press
[TAKE] to select 9600, 19.2K or 38.4K to match baud rate on what the
AMEZI card is configured for.
11)
Turn the wheel until the display says “Protect.”
12)
Press [TAKE] to enable or disable Protecting Destinations.
13)
Turn the wheel until the display says “UNUSED LVLS:”
14)
Press [TAKE] to select sending the status of unused levels as “NOT-
Connected” or “DISABLED.”
15)
Turn the Wheel until the display says “Set STROBE.”
16) Press
[TAKE].
17)
The display shows current strobe (level) number.
18)
Turn the Wheel to select level 1-4.
19) Press
[ESC] twice to exit SETUP MENU.
Setup is complete. The GV7000 can now control the SW32PS.
NOTE: Default settings for communications are: RS422, 34.8, No parity, 8 bits data,
1 stop bit.