beautypg.com

DNF Controls USP3-SBX-VSS User Manual

Page 6

background image

5. REMOTE DEVICE ASSIGNMENT WEB PAGE

Remote Device Label Enter up to 32 characters. The first 12 characters will be displayed on the

ShotBox key when the MENU key is pressed.

Device Type Spyder

Connection Type Greyed out

Connection Mode Greyed out

UDP Attempts Greyed out

IP Address Enter IP address for Spyder to be controlled

Port Number Greyed out

Heartbeat Rate Set heartbeat polling rate. 5 seconds is the recommended setting

Connection Status Displays “Connected” in green when communicating with Spyder.

Displays “---------“ when NOT communicating with Spyder or no IP address
has been entered.

NOTE- The ShotBox will display “WAITING FOR SPYDER” across its keys
when it is not able to communicate with the selected Spyder.

Save Button Click on Save button to save entered settings

Refresh Link Click on Refresh link to refresh Connection Status


NOTE- The ShotBox will display “WAITING FOR SPYDER” across its keys
when it is not able to communicate with the selected Spyder.

Check:

The IP address entered for this Spyder

The Ethernet connection to the ShotBox

The left amber light on the RJ45 should be on

The right green light on the RJ45 shows network activity

USP3-SBX-VSS User Manual

Page 6 of 10