DNF Controls Analyst, RS422/RS232 Tester User Manual
Page 24

MONITOR Screen- RS422
DIR
ÎÎ
Affect data communication path from IN port to OUT port
IN
Î ÎÎ communication from Controller to Device
RS422
ÍÍ communication from Device to Controller
Rx+
Norm
RxTx
Norm
Dir
ÎÎ
More
Exit
MON.
Disp
Run
Tx+
Norm
Sw #1
Sw #2
Sw #3
Sw #4
Sw #5
Sw #6
Sw #7
Sw #8
DIR
ÍÍ
Affect data communication path from OUT port to IN port
Í OUT ÎÎ communication from Controller to Device
RS422
ÍÍ communication from Device to Controller
Tx+
Norm
Dir
ÍÍ
More
Exit
MON.
Disp
Run
RxTx
Norm
Rx+
Norm
Sw #1
Sw #2
Sw #3
Sw #4
Sw #5
Sw #6
Sw #7
Sw #8
[RX+] Swap polarity of receive lines (RS422 only)
[RxTx] Swap transmit and receive lines
[Dir]
Affect data communication path from IN port to OUT port (
ÎÎ)
Or, affect data communication path from OUT port to IN port (
ÍÍ)
[More] Select More screen
[Exit]
Exit Monitor Mode. Return to MAIN screen.
[Disp] Display mode- Run: Update display with received data
Pause: Do not update display with received data
[Tx+]
Swap polarity of transmit lines (RS422 only)
Page
20
of 31
The Analyst RS422/RS232 Tester