Matrix-1000™

44

4

5

TROUBLESHOOTING GUIDE

Problem Suggestion

One Shot or Phase Mode
using serial trigger
source:
no image is displayed in
Visiset™ Calibration Tool
window while your trigger
source is transmitted on the
reader serial port.

In the Operating Mode folder check the settings
for Phase-ON, Acquisition Trigger and
Phase-OFF parameters.

Are the COM port parameters (Baud Rate,

Parity, Data Bits, Stop Bits, Handshake)
correctly assigned?

In the communication folder, check the settings

of Phase-ON String, Acquisition Trigger
String
and Phase-OFF String parameters.

Is the serial trigger source correctly connected?

Phase Mode:
no result is transmitted by
the reader at the end of the
phase collection.

In the Operating Mode folder check the
Phase-OFF parameter setting.

In the Data Collection folder check the settings
for the COLLECTION, DATA FORMAT and
STATISTICS parameter groups.

Reading:
the reader always transmits
the No-Read Message

Position the reader as described in par. 2.5 and
through the VisiSet™ Calibration Tool:
-

Tune the DELAYED TRIGGERS, if the
moving code is out of the reader field of
view;

-

Set the Continuous Operating Mode if no
external trigger source is available;

- Tune the ACQUISITION RECIPE to

improve the code image quality;

-

Check the parameter setting in Decoding,
2DCodes, 1Dcodes, and Postal Codes
folders;

-

View the full resolution code image to
check the printing or marking quality.

Communication:
reader is not transmitting
anything to the host.

Is the serial cable wiring correct?

Are the host serial port settings the same as the

reader serial port settings?

Communication:
data transferred to the host
are incorrect, corrupted or
incomplete.

Are the host serial port settings the same as the

reader serial port settings?

In VisiSet

 Communication folder check the

settings of Header and Terminator parameters.

In VisiSet™ Data Collection folder, check the

settings of DATA FORMAT parameter group.