Datalogic Scanning MATRIX 1000 User Manual
Page 48
Matrix-1000™
38
3
Figure 36 - Example out of FOV
Moving code out of the Field of View:
To correct this result and have the code completely visible in the F.O.V., it is possible
to follow one or both the procedures listed below:
•
reposition the reader
•
use the Delayed Trigger by tuning the Delay Time (x 100 µs)