INSTALLATION

17

2

2.3.3

Auxiliary RS232 Interface


The RS232 auxiliary interface is available for Point-to-Point connections. When it is
connected to the host computer it allows both transmission of code data and reader
configuration by VisiSet™.

Its communication parameters (baud rate, data bits, etc.) can be defined by the
user. For more details refer to the "Communication" folder in the VisiSet™ Help
On Line.

The RS232 interface is available on both Matrix-1000™ D-sub connectors with the
following pinouts:

9-Pin 25-Pin

Name

Function

2 21

TXAUX

Transmitted

data

3 20

RXAUX

Received

data

5 23

GND

Ground


MATRIX

21

TXAUX

RXAUX

20

USER INTERFACE

RXD

TXD

23

GND

Ground

Earth
Ground

1

SHIELD

Figure 15 - RS232 Interface Connections Using 25-pin Connector


MATRIX

2

TXAUX

RXAUX

3

USER INTERFACE

RXD

TXD

5

GND

Ground

Figure 16 - RS232 Interface Connections Using 9-pin Connector