Chapter 4 – DFI KS210-IMX6 Manual User Manual
Page 29

www.dfi .com
29
Chapter 4 Ports and Connectors
Chapter 4
RTC Battery
The RTC Battery powers the real-time clock and CMOS memory. It is an auxiliary source of
power when the main power is shut off.
Safety Measures
• Danger of explosion if battery incorrectly replaced.
• Replace only with the same or equivalent type recommend by the manufacturer.
• Dispose of used batteries according to local ordinance
.
RTC
Battery
1
+3.3V
GND
2
Connect to the battery connector
Battery
Power Switch
Power
Switch
1
Power_Enable
GND
2
Power Switch
The power switch is used to power on or power off the system.