Independent from the power supply of the heat emitter,
the Pilot Wire is used to send the Comfort
,
Economy
, Frost Protection
or Shutdown
orders requested by the programmer.
The required temperature is set on the thermostat of
each heat emitter (convectors, panel heaters, under-
floor heating or radiant ceiling heating, towel warmer
radiators, storage heaters, etc.)..
Pilot Wire
order
(mode)
Setting on the heat emitter
Room
temperature
Comfort
Comfort setting (thermostat knob)
example : 19°C
Economy
Economy setting (thermostat knob)
example : 16°C
or Comfort –X°C
(depending on heat emitter model)
Absence
Frost protection set to 7°C or 8°C
(depending on model)
Shutdown
Heating shutdown
19°C
16°C
7°C or 8°C
No heating
Presentation
This unit optimizes the energy management of your
home:
• Comfort or Economy programming for the heating in
2 zones (CALYBOX 220 or 420) or 3 zones (CALY-
BOX 230 or 430),
• reduction in the subscription costs by preventing the
circuit-breakers from tripping when the electricity
consumption is too great (load shedding),
• indication of the electricity consumption of the sys-
tem.
This unit is compatible with the domotics products of
the Delta Dore range (door/window magnetic contacts,
remote controls, control unit, transmitter, etc.).
The CALYBOX 420 or 430 can control your alarm by
means of a badge, ref.: 6413224 (supplied).
To control the heat emitters, the programmer uses the
Pilot Wire.
IMPORTANT: The heat emitter must be in automatic
mode (PROG, AUTO,
, etc. depending on model).
Pilot wire
Pilot Wire
orders
Heat emitters
Programmer
- 3 -