Dataprobe 8PK-SCS User Manual
Page 4

Model 8PK-SCS
Page 4
2) Relay Control
This selection allows control of the relays in the 8PK-SCS.
1) Eng SWITCH1
2) Eng SWITCH2
3) Den SWITCH3
4) Eng SWITCH4
5) Eng SWITCH5
6) Eng SWITCH6
7) Den SWITCH7
8) Eng SWITCH8
# - Select relay to toggle
P# - Pulse relay
X - Exit
Enter >
Again, each relay can be named. Eng and Den display the current status of the relay, Energized or
De-energized. To toggle the relay, simply enter the relay number, followed by Enter.
The relay can also be cycled (pulsed) by entering P plus the number. (i.e. P1 to cycle relay number 1)
The length of time the relay pulses is preset through the programming menu. While the relay is cycling,
a message will be displayed.
3) Programming
1) Device labels
2) Password
3) Baud: 19200
4) Parity/Data: N,8
5) Lead: N
6) Resp: Y
7) Mode: Modem
8) Cycle time: 5
9) Time out: 0
X) Exit
Enter > 1