beautypg.com

Specifications – Dataprobe T-APS Rack User Manual

Page 22

background image

Specifications

T1 Interface

Bit Rate

1.544 M b/s

Line Code

AMI B8ZS

Frame Format

SF

ESF

Unframed

Bit Rate

1.544M b/s

Impedance

100 Ohms Resistive Balanced

Input Level

0-36 dB

Output Level

6V p-p

Line Build Out

0-655 feet

E1 Interface

Bit Rate

2.048 M b/s

Line Code

AMI

HDB3

Frame Format

CCS CAS

CCS+CRC

CAS+CRC

Unframed

Impedance

120 Ohms Resistive Balanced

Input Level

0-43 dB

Output Level

6V p-p

Line Build Out

0-655 feet

LED Status Display

RUN 1+1/1:1, T1 or E1, Line 1 and Line2, LOS, OOF, AIS, RAI, Fail.

ALARM Contacts

Form C relay 0.5A 30VDC MAX

Automatic Switching Parameter Programmable

Code Violation

10-3

10-6

CRC Error

10-1

10-3

Frame Error

10-1

10-3

AIS

Unframed

Loss of Signal
Fault Duration

Recovery Interval

0 Minute

1~98 Minutes 99 Minutes (Toggle)

Console Port

RS-232

(VT-100)

Network 10BaseT Ethernet
Power

-48V±5V DC standard, optional 110 -230VAC, 50-60Hz

Weight

1.1 KG

Dimension

482mm W × 177mm H × 267mm D, 19.0in W x 7.0in H x 10.50in D

Operating Temperature

0ºC~50ºC

Relative Humidity

5% 90%,Non-condensing

Regulatory Compliance

FCC Part 15 Class A

Reliability

MTBF 44,000 hrs