Dataprobe T-APS Rack User Manual
Page 13

T1/E1 Auto Protection Switch 1+1, 1:1 or Blind
Comparison Chart
Item
Function
1+1
1:1
Blind 1 Blind 2
1
Switching Time (within)
12ms
25ms
12ms
12ms
2
Ability to retrieve protection path status (Good or Bad)
from CO or CPE.
No
Yes
No
No
3
Ability to provide protection path status (Good or Bad)
from LOS only
Yes
Yes
Yes
No
4
Manual switching to working path on both ends (CO or
CPE)
No
Yes
No
No
5
Single Ended Application
Yes
No
Yes
Yes
6
Duplicate CPE Signal in both Active and Protective
Path
Yes
No
Yes
No
Note: Referring T-APS installed in both CO to CPE sides
CO: Central Office
CPE: Customer Premises Equipment
Redundant CPE Applications
The T-APS can be used for switching a T1/EI circuit between two sets of CPE for redundant equipment
operation. The Working Mode selection can be either 1+1, Blind 1 or Blind 2.
In the 1+1 and Blind 1 modes, TX signals from the CO will be present at each of the two CPE devices.
In Blind 2 mode only the current selected working path will see the TX signals. The alternate path will not
provide TX to it’s associated CPE while the Protective Path is working.