Daktronics AF-3090-89-R,A User Manual
Page 33

Maintenance &
Troubleshooting
4-8
4.7
Optional Temperature Sensor Electrical Installation
Reference Drawings:
Temp Sensor Mounting .............................................................................Drawing A-79767
Signal Input, Venus 1500.........................................................................Drawing A-129110
After mounting the optional temp sensor, follow these steps to complete the electrical installation. A
2-pair, individually shielded cable (Belden 5594, Daktronics part number W-1234) is used to connect
the sensor to the controller.
1. Run ½
″
conduit from the sensor location to the controller within the display. The cable must be
routed through one-foot of ½
″
metal conduit that should be earth-grounded to protect the sensor
and controller form lightning damage.
2. Connect the cable to the temperature sensor terminal block within the temperature sensor as
follow:
Wire Color
Terminal Block
Red
V+
Green
P
Black
GND
White
N
3. Install the mesh screen with the four screws enclosed.
4. Disconnect power to the display before attaching the cable
5. Connect the cable to the temperature sensor terminal block on the controlle r (TB7) per the
following table:
Wire Color
Terminal Block TB7
(Temp In)
Pin 1 (+5)
Pin 2 (GND)
Pin 3 (Light +)
Pin 4 (Light -)
Green
Pin 5 (Temp +)
White
Pin 6 (Temp -)
Red
Pin 7 (+5V)
Black & Shield
Pin 8 (GND
OR Bare (shield)
Pin 8 (GND)
To connect the temperature sensor to multiple displays (such as a double -face display):
Wire Color
Display 1 TB7
Display 2 TB7
Green
Pin 5 (Temp+)
Pin 5 (Temp +)
White
Pin 6 (Temp -)
Pin 6 (Temp -)
Red
NC
NC
Black
NC
NC