Optional Temperature Sensor Electrical Installation

Reference Drawings:

Temp Sensor Mounting .............................................................................Drawing A-79767

Signal Input, Venus 1500.........................................................................Drawing A-129110


After mounting the optional temp sensor, follow these steps to complete the electrical installation. A
2-pair, individually shielded cable (Belden 5594, Daktronics part number W-1234) is used to connect
the sensor to the controller.

1. Run ½

conduit from the sensor location to the controller within the display. The cable must be

routed through one-foot of ½

metal conduit that should be earth-grounded to protect the sensor

and controller form lightning damage.

2. Connect the cable to the temperature sensor terminal block within the temperature sensor as

follow:

Wire Color

Terminal Block

Red

V+

Green

P

Black

GND

White

N


3. Install the mesh screen with the four screws enclosed.
4. Disconnect power to the display before attaching the cable
5. Connect the cable to the temperature sensor terminal block on the controlle r (TB7) per the

following table:

Wire Color

Terminal Block TB7

(Temp In)

Pin 1 (+5)

Pin 2 (GND)

Pin 3 (Light +)

Pin 4 (Light -)

Green

Pin 5 (Temp +)

White

Pin 6 (Temp -)

Red

Pin 7 (+5V)

Black & Shield

Pin 8 (GND

OR Bare (shield)

Pin 8 (GND)


To connect the temperature sensor to multiple displays (such as a double -face display):

Wire Color

Display 1 TB7

Display 2 TB7

Green

Pin 5 (Temp+)

Pin 5 (Temp +)

White

Pin 6 (Temp -)

Pin 6 (Temp -)

Red

NC

NC

Black

NC