Daktronics AF-3090-89-R,A User Manual
Page 30

Maintenance &
Troubleshooting
4-5
Controller
The controller sends data to the modules. Refer to the signal summary in Section 4.3 for more
information and to the component location drawings for the position of the controller board.
Figure 21 illustrates a typical controller.
“DIP” switches are located on the controller’s MDC. The DIP switches set the hardware address,
which the software uses to identify that particular display. When replacing a controller board, be
sure to set the DIP switches in the same address configuration as the defective controlle r.
NOTE: Setting the DIP switches to address 0 (turn all the switches to OFF by flipping them
toward the printed switch numbers) can activate a test mode. The display’s power must be turned
off and then turned back on to run the test mode.
Switch
8
Switch
7
Switch
6
Switch
5
Switch
4
Switch
3
Switch
2
Switch
1
Address
Off
Off
Off
Off
Off
Off
Off
Off
Test Mode
Off
Off
Off
Off
Off
Off
Off
On
1
Off
Off
Off
Off
Off
Off
On
Off
2
Off
Off
Off
Off
Off
Off
On
On
3
Off
Off
Off
Off
Off
On
Off
Off
4
Off
Off
Off
Off
Off
On
Off
On
5
Off
Off
Off
Off
Off
On
On
Off
6
Off
Off
Off
Off
Off
On
On
On
7
…
…
…
…
…
…
…
…
…
On
On
On
On
Off
Off
Off
Off
240
Figure 21:Controller