Dimming, Dimming automatic, Set auto dimming max intensity – Daktronics DF-2100 User Manual

Page 46: Intensity xx, Enter to set

background image

38

RC-100 Controller

Dimming

The dimming level of the rate display can be adjusted in two ways. A temperature/light
sensor mounted near the display can detect the level of ambient light at the display location
and dim the sign's LEDs accordingly. This function is known as automatic dimming. When
the manual dimming function is selected, the LEDs remain at the same level of brightness
regardless of the level of light detected at the display. To select either of these functions,
press [Dimming]. The current setting is shown on the bottom line of the LCD.

LCD Screen

Action

DIMMING
AUTOMATIC



Press the down arrow key <

> to toggle

through dim settings:

Automatic – The display automatically dims

based on the light detected at the display

Manual – The display dimming level is set

manually. Once set, this value remains

regardless of the level of light detected at the

display.

Blank Sign – The display can be blanked

out without powering down. Refer to the

blank sign section for details.

SET AUTO
DIMMING
MAX INTENSITY?



Press the [Enter/Edit] key to edit the auto

dimming max intensity. This is the maximum

intensity that the display will use in full-bright

modes (during daylight hours.)

Press [Clear] to keep the current auto

dimming maximum setting

INTENSITY
XX

↓↑

ENTER TO SET

XX – Current intensity (1-16)

Max Intensity - 16


Press the up or down arrow key <

↓> to

modify the current intensity of the display

(Note: The DataMaster must be connected

to the display)

Press [Enter] to accept this intensity. If

manual dimming mode is selected, this will

be the new intensity for the display. If the

automatic dimming mode is selected, the

display will illuminate in full-bright mode,

which is the maximum intensity level.

This manual is related to the following products: