Power, Power requirements, Grounding – Daktronics KE-1010-7.6-RG User Manual
Page 19: Power -3, Power requirements -3, Grounding -3, 2 power

Electrical Installation
3-3
3.2 Power
Reference Drawings:
Shop Drawings .......................................................... Refer to Appendix A
Power Requirements
Refer to the following tables and the drawings referenced above for voltage and
current requirements. The displays are sufficiently powered by a 120 VAC single-
phase outlet. For multiple section displays, each display section requires a
separate outlet.
Do not connect any display to voltage other than that listed on the Daktronics
product label attached to the back of the display.
Power Specifications for Individual Sign Sizes (Master & Echo)
Sign
Size
Amps Per Line
(120VAC)
Max
Watts
16x200 0.9
100
16x240 1.0
120
16x320 1.4
160
16x400 1.7
200
24x200 0.9
120
24x240 1.0
140
24x320 1.4
160
24x400 1.7
200
2-16x200 1.7
200
2-16x240 2.0
240
2-16x320 2.7
280
2-16x400 3.4
400
Power Specifications for Tickers Built Using Multiple Sections
# of Phases
1
Amps Per
Line (120VAC)
Sum Of Amps For All Sections (see
above table)
Max Watts
Sum Of Watts For All Sections (see
above table)
Voltage –
Secondary
5VDC
Grounding
Proper grounding is necessary for reliable equipment operation and provides some
protection to the equipment from damaging electrical disturbances. All of the
displays are supplied with a power cord that contains an earth ground conductor.
Make sure to plug this cord into a grounded outlet. If the proper grounding methods
are not followed, the warranty will be void.