Replacement parts, Replacement parts -7, 6 replacement parts – Daktronics KE-1010-7.6-RG User Manual
Page 31

Maintenance &
Troubleshooting
4-7
Display is garbled or sequence is shifted.
•
Check the settings on the data feed PC.
•
Check signal connections
•
Refer to the data feed manual.
A group of modules does not work.
•
Check for output from power supplies.
•
Reboot power to the section.
•
Check/replace ribbon cable.
•
Replace/move the first module not working.
•
Replace/move the last working module of the
previous section.
•
Check signal connections.
Entire display does not work.
•
Check 120 VAC input power to 1
st
display
section.
•
Check all signal connections.
•
Check PC/Feed setting for proper orientation.
•
Replace controller.
Data feed or software not operating properly.
•
Refer to data feed manual.
•
Check signal connection feed to display
•
Contact data feed/software provider.
Display resets and restarts
•
Reduce the amount of amber pixels used
•
Remove inverted text
4.6 Replacement
Parts
Part Description
Daktronics Part #
Controller Board (16-high, RS422 Input)
0P-1182-0011
Controller Board (16-high, RS422 or Ethernet Input)
0P-1182-0022
Controller Board (24-high, RS422 or Ethernet Input)
0P-1182-0023
Shift Board (16-high)
0P-1182-0012
Shift Board (24-high)
0P-1182-0019
Module; 16x40 Super Bright Red-Green
0P-1182-0014
Module; 24x40 Super Bright Red-Green
0P-1182-0018
Signal Converter; RS232 to RS422
0A-1127-0255
Serial Cable, DB9 to DB25, from PC to Signal Converter
W-1249
Ribbon Cable; 20 Cond. 28 AWG (Between Modules)
W-1357
Ribbon Cable; 20 Cond. 28 AWG
(Controller to shift card and shift card to module)
W-1387
Power Supply; +5VDC
A-1632
Digital Light Sensor
0P-1151-0002
Power Cord; 3-Prong 120VAC
W-1181
Splice Bar
EN-1772
Mounting Clip
0M-113394
Section Cup, 2 ¼” Dia.
HS-1338
Filter; RFI Line
Z-1002
Face Panel; 16x240
0A-1182-0015
Face Panel; 16x320
0A-1182-0016
Face Panel; 16x400
0A-1182-0017
Wall Mounting Bracket; 0
° Tilt
0M-117501
Wall Mounting Bracket; 15
° Tilt
0A-1182-0019