Redundancy controller auto/manual, Redundancy controller toggle, Set physical address – Comtech EF Data CSAT-6070 User Manual
Page 72

5 to 25 Watt C-Band Transceiver
Revision 0
System Operation
MN/XSAT607025.IOM
whether or not the redundancy controller will switch on a LNA current alarm in the
redundant configuration. (The factory default is 0)
Associated Remote Command(s):
LFL=
Example(s) LFL=0
3.3.16 R
EDUNDANCY
C
ONTROLLER
A
UTO
/M
ANUAL
The Operating mode of the Comtech EF Data Redundant Switch Unit (RSU-5060) can be
set via a command to the ONLINE CSAT. The RSU-5060 initializes to the AUTO mode
when power is first applied.
• In AUTO mode the RSU-5060 monitors the state of the two CSATs and will
automatically switch the OFFLINE unit online if the ONLINE unit faults.
• In MANUAL mode, the RSU-5060 will only switch the position of the Tx and Rx
transfer switches when commanded to do so via either the RTG= command or via
Pin V on the ‘M&C Control’ connector (J5) on the RSU-5060. The user sets
AUTO mode by sending a ‘1’ in the data field and MANUAL mode with a ‘0’ in
the data field.
Associated Remote Command(s):
RAM=
Example(s) RAM=1
3.3.17 R
EDUNDANCY
C
ONTROLLER
T
OGGLE
The User can cause the RSU-5060 Redundant Switch Unit to switch the position of both
the Tx and Rx transfer switches using this command.
• If the RSU-5060 is in AUTO mode, the command will only cause a switchover if
the OFFLINE unit is currently UNFAULTED.
• If the RSU-5060 is in MANUAL mode, the command will cause a switchover
independent of the state of the OFFLINE unit.
Associated Remote Command(s):
RTG=
Example(s) RTG=
3.3.18 S
ET
P
HYSICAL
A
DDRESS
The Remote (Physical) address to which the CSAT will respond can be set to any value
between 0001 and 9999. (The factory default is 0001)
Associated Remote Command(s):
SPA=
Example(s) SPA=0001
3–8