Rsu-5060 operation, Peration – Comtech EF Data CSAT-6070 User Manual
Page 101

5 to 25 Watt C-Band Transceiver
Revision 0
Redundant Systems
MN/CSAT607025.IOM
B.3 RSU-5060 O
PERATION
The RSU-5060 is designed to provide single-point control for both the Tx and Rx transfer
switches (Waveguide Switches). In addition, the RSU-5060 provides the customer with a single
interface connection to his M&C system. Through this interface the customer can access and
control all configuration, monitor and faults status parameters of both CSAT’s. The RSU-5060 is
a ‘smart box,’ the unit contains a microcontroller running algorithms to process status and
command information from the two CSAT’s and control the Tx and Rx waveguide switches
accordingly. A functional block diagram of the RSU-5060 is shown in Figure B-2.
RS485 Tx+
RS485 Tx-
RS485 Rx+
RS485 Rx-
RS485 Tx+
RS485 Tx-
RS485 Rx+
RS485 Rx-
RS485 Tx+
RS485 Tx-
RS485 Rx+
RS485 Rx-
Micro
Controller
A AUXCOM Td
A AUXCOM Rd
B AUXCOM Td
B AUXCOM Rd
RS232 line
Drives and
Recievers
&
Multiplexer
Td
Rd
a
b
c
A FAULT N.O.
REDUNDANCY A*
POSITION A*
REDUND_FLT*
B FAULT N.O.
REDUNDANCY B*
POSITION B*
REDUND_FLT*
B SELECT*
CSAT A
+24 VDC
CSAT B
+24 VDC
Rx
TRANSFER
SWITCH
Tx
TRANSFER
SWITCH
POS A CMD
POS B CMD
POS A IND
POS B IND
POS A CMD
POS B CMD
POS A IND
POS B IND
Signal
Conditioning
RED AUTO/MAN
SWITCH CMD
A ONLINE CLOSED
B ONLINE CLOSED
A FAULT OPEN
B FAULT OPEN
Customer
Monitor
&
Control
RSU-5060
Figure B-2 RSU-5060 Functional Block Diagram
B–7