beautypg.com

Rf converter module, Reference oscillator module, Lna current fault – Comtech EF Data CSAT-6070 User Manual

Page 95: Fan fault, Temperature fault

background image

50 Watt C-Band Transceiver

Revision 0

Maintenance and Troubleshooting

MN/CSAT607050.IOM


C.3.2 RF C

ONVERTER

M

ODULE

Synthesizer and IFLO Lock Detect Fault:

During normal operation, neither the Upconverter nor the Downconverter
synthesizer or IFLO should experience a Lock Detect fault.

• If one or more of these functions is faulted the transceiver will not

function properly.

• If a fault condition exists and an EXT REF is being used, check the

connection to the transceiver and make sure it is secure.

• It may be necessary to remove the EXT REF if it is faulty.

• If the fault still exists, contact Comtech EF Data Customer Support .

C.3.3 R

EFERENCE

O

SCILLATOR

M

ODULE

Reference Lock Detect:

A fault ("FT") indicates that the reference oscillator is not locked. Check all
connections to the converter module to make sure they are secure. If the fault still
exists, contact Comtech EF Data Customer Support.

C.3.4 LNA C

URRENT

F

AULT

LNA Current Fault:

This can indicate either a problem in the CSAT LNA current source circuitry or a
problem with the LNA.

• First, insure that the LNA is connected and that no shorts exist. Use the

RMS? Command to query the measured LNA current.

• If the LNA and cable are OK, proceed to disconnect the LNA and measure

from the center conductor of the cable to the shield of the cable using a
DVM. A voltage of 11Vdc shall be measured if the LNA Current Source
is Enable (i.e. LCS=1).

• Contact Comtech EF Data Customer Support for further troubleshooting.

C.3.5 F

AN

F

AULT

Fan Fault:

Contact Comtech EF Data Customer Support for troubleshooting help.


C.3.6 T

EMPERATURE

F

AULT

C-3