MN/CSAT607050.IOM
3.1.2 C
ONNECTOR
J5: COMM,
R
EMOTE COMMUNICATIONS PORT
.
Mating connector: ITT: KPT06J14-19P or
MS3116J14-19P
Connections, see the following table:
Pin Signal
I/O
Notes
A
EIA -485 +RX
Input
CSAT Receive Line
B
EIA -485 –RX
Input
CSAT Receive Line Compliment
C
EIA -485 TX+
Output
CSAT Transmit Line
D
EIA -485 TX-
Output
CSAT Transmit Line Compliment
E
EIA -232 Rd
Input
CSAT Receive Line
F REDUNDANT
FAULT Input Redundant Controller Status Input
G
EIA -232 Td
Output
CSAT Transmit Line
H
AUXCOM Rd
Input
Auxiliary RS232 Rd used with Redundant Controller
J
AUXCOM Td
Output
Auxiliary RS232 Td used with Redundant Controller
K FAULT
COMMON
Output
L
FAULT NORM OPEN
Output
Open(OK) / Short(Fault)
M
FAULT NORM CLOSED Output
Short(OK) / Open(Fault)
N
ADDRESS SELECT
Input
Redundant Addressing
P ONLINE
STATUS
Input Input
from Redundant Controller
R
+24V AUX
Output
24V output to power Redundant Controller
S
REDUNDANCY
Input
Open (stand-alone) / Gnd (Redundancy)
T GROUND
Passive
U GROUND
Passive
V NO
CONNECT