Redundancy controller toggle, Set physical address, Set baud rate – Comtech EF Data CSAT-6070 User Manual
Page 63: Set date

/50 Watt C-Band Transceiver
Revision 0
System Operation
MN/CSAT607050.IOM
3.3.17 R
EDUNDANCY
C
ONTROLLER
T
OGGLE
The User can cause the RSU-5060 Redundant Switch Unit to switch the position
of both the Tx and Rx transfer switches using this command.
• If the RSU-5060 is in AUTO mode, the command will only cause a
switchover if the OFFLINE unit is currently UNFAULTED.
• If the RSU-5060 is in MANUAL mode, the command will cause a
switchover independent of the state of the OFFLINE unit.
Associated Remote Command(s):
RTG=
Example(s): RTG=
3.3.18 S
ET
P
HYSICAL
A
DDRESS
The Remote (Physical) address to which the CSAT will respond can be set to any
value between 0001 and 9999. (The factory default is 0001)
Associated Remote Command(s):
SPA=
Example(s): SPA=0001
3.3.19 S
ET
B
AUD
R
ATE
The Baud Rate of the communication port, J5, can be set to any values shown
below:
1200, 2400, 4800, 9600, 19200, 38400 (The factory default is 9600)
Associated Remote Command(s):
SBR=
Example(s): SBR=9600
3.3.20 S
ET
D
ATE
The CSAT contains a battery powered Real Time Clock (RTC) used to provide
Date/Time stamping of events, alarms and faults. The date can be changed by the
user.
Associated Remote Command(s):
DAY=
3-9