Modulatorstatus, A.7.97 modulatorstatus, A.7.97 – Comtech EF Data CiM-25/9000 User Manual
Page 121

CiM-25/9000 IP Enabled M&C
Rev. 1
SNMP Interface
CD/CIM259000.IOM
103
A.7.97
MODULATOR
S
TATUS
Name
modulatorStatus
OID
1.3.6.1.4.1.6247.16.1.6.9
Full path
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtech(624
7).sdm9000(16).sdm9000Objects(1).statusParameters(6).modulator
Status(9)
Module
SDM9000
Parent
statusParameters
Prev sibling
modemFaultStatus
Next sibling
demodulatorStatus
Type
OBJECT-TYPE
Numerical syntax
SNMP_SYNTAX_INT
Base syntax
INTEGER
Composed syntax
INTEGER
Status
current
Max-access
read-only
Size list
1
0..2047
Description
Modulator Fault Status. (MS_)
Bit 0 = Module (0=OK, 1=FLT)
Bit 1 = IF Synthesizer (0=OK, 1=FLT)
Bit 2 = Data Clock Activity (0=OK, 1=FLT)
Bit 3 = Data Clock Synthesizer (0=OK, 1=FLT)
Bit 4 = I Channel (0=OK, 1=FLT)
Bit 5 = Q Channel (0=OK, 1=FLT)
Bit 6 = AGC Level (0=OK, 1=FLT)
Bit 7 = Internal SCT Synthesizer (0=OK, 1=FLT)
Bit 8 = External Ref Activity (0=OK, 1=FLT)
Bit 9 = Programming (0=OK, 1=FLT)
Bit 10 = Configuration (0=OK, 1=FLT)