Step
Procedure
Troubleshooting
1
From the Controller Server, PING
the Local Client and verify 100%
response with average delay of
< 30 msec.
A failed PING attempt between the
Controller Server and the Local Client
shall not occur if they are on the same
physical sub-network unless serious
NIC problems exist (hardware or
driver).
2
From the Local Client, PING the
Controller Server and verify 100%
response with average delay of
< 30 msec.
A failed PING attempt between the
Controller Server and the Local Client
shall not occur if they are on the same
physical sub-network unless serious
NIC problems exist (hardware or
driver).
3
Attempt to PING to and from the
Local Client from any other device
in the network and verify no re-
sponse.
If any other network device can PING
the Controller Server or the Local Cli-
ent, verify IP Address and Subnet
Mask settings.
M
M
I
I
D
D
A
A
S
S
N
N
M
M
S
S
C
C
o
o
n
n
f
f
i
i
g
g
u
u
r
r
a
a
t
t
i
i
o
o
n
n
C
C
o
o
n
n
t
t
r
r
o
o
l
l
l
l
e
e
r
r
–
–
N
N
M
M
S
S
S
S
e
e
r
r
v
v
e
e
r
r
The network changes to prepare for the installation of MIDAS 4 comprise
routing and filtering settings. The MIDAS Controller and the MIDAS NMS
Server need to be together on a sub-network that is isolated from all non-
MIDAS traffic. This can be accomplished several ways.
• A connection using a 10/100 BaseT hub.
• A connection using a 10/100 BaseT Layer 2 Switch or Router.