B.3 parameter semantics – Comtech EF Data CMR-5950 Manual User Manual
Page 55
CMR-5950 Digicast Media Router Inline Scrambler (IS)
Revision A
BISS E Control via SimulCrypt Interface MN/INLNSCRDC.IOM
B.3 Parameter
Semantics
service_index: service being controlled. The scrambler supports 15 services. The valid
range is 0-14.
BISS_mode: BISS mode. 0 = BISS0, 1=BISS1, 2=BISSE using buriedID, 3=BISSE
using injectedID.
key_select: select the key. 0=even, 1=odd.
sw: clear session word. Valid for BISS1 only.
esw: encrypted session word. Valid for BISSE only.
injected_ID: injected ID used to decrypt the encrypted session word. Only valid if BISS
mode is BISSE with injected ID.
buried_ID: buried ID used to decrypt the encrypted session word. Only valid if BISS
mode is BISSE with buried ID.
Connect Message: IS ! Host
The connect message is used to indicate the Host is starting. Only valid if the
inline scrambler remote connection mode is TCP.
Disconnect Message: IS ! Host
The disconnect message is used to indicate the Host is finished. Only valid if the
inline scrambler remote connection mode is TCP.
Set BISS mode: IS ! Host
Parameter
Number of instances
service_index 1
BISS_mode 1
Used to set the operating mode of a BISS service.
Set Key: IS ! Host
Parameter
Number of instances
service_index 1
key_select
1 or 2
sw or esw
1 or 2
Used to set the value of a key. Both the evan and odd keys may be set in one
message but key_select MUST proceed the sw/esw.
Example: