CMR-5950 Digicast Media Router Inline Scrambler (IS)
Revision A
Device Management via User Interfaces MN/INLNSCRDC.IOM
4.2.6.2 Inline
Scrambler
! BISS Remote Control Configuration
Figure 4-10. BISS Remote Control Configuration page
This page provides configuration options for the BISS Remote Control Configuration.
These parameters must be set if the CA keys are to be remotely modified by a control
program.
Enabled
Enables or Disables the remote control capability of the IS.
Mode
Selection of either UDP or TCP as the transport for the remote control
information.
Port
Selection of the desired Port for sending remote control information. The Port
address should be a value greater than 1024.
Keep alive in seconds (TCP only)
The number of seconds between keep alive messages when using TCP mode for
the remote control transport.
Login Required
A user name and password are required to make any changes to the IS
configuration.
4-10