Fitting the eq security cover – Cloud Electronics 46-50 User Manual
Page 23
46-50 Installation and User Guide V1.0
23
6. Plug the 2-pin connectors on the other end of the flying
lead assembly onto the corresponding headers on the
46-50 main PCB (immediately behind the
100V/70V
LINE OUTPUTS). The wire pairs are colour-coded for
ease of identification. Note that any or all of the four
channels may be connected as required.
7. Enable the 65 Hz high-pass filters for the relevant channels
(J7, J9, J16 & J18). See page 24 for jumper locations.
8. Fit the two hex spacers supplied to the holes vacated in
Step 2 using the same screws, nuts and washers.
9. Replace the cover.
After connecting the 70/100 V-line loudspeaker system
(see page 17), fit the blanking plate from Step 2 onto the
hex spacers (Step 8) over the connector, with the printed
warnings outwards.
Fitting the EQ security cover
A security cover is supplied with the 46-50 which can be fitted
to the front panel to prevent access to the Zone EQ preset
controls. The
MIC LEVEL, MUSIC LEVEL and SOURCE
controls remain accessible and the
CLIP LED is still visible.
The panel is simply placed over the rotary control knobs
and secured in place with the four M3x6 hex-head screws
supplied.