Product overview
Technical data
Technical data
EL9570
Technology
buffer capacitor
Nominal voltage
50 V
Capacity
500 µF
Ripple current
10 A in continuous operation
Internal resistance
< 10 mΩ
Surge voltage protection
> 56 V
Recommended ballast resistor
10 Ω, 10 W typ.
Overvoltage control range
±2 V
Ballast resistor clock rate
loaddependent, 2point control
Electrical isolation
1500 V
Diagnostics
Message to EBus
PE contact
no
Shield connection
Current consumption from EBus
Bit width in the process image
0
Electrical connection to mounting rail
Electrical isolation
Side by side mounting on EtherCAT Terminals with
power contact
yes, left side without PE
Side by side mounting on EtherCAT Terminals
without power contact
yes
Configuration
no address or configuration settings
Weight
approx.. 90 g
Permissible ambient temperature range (during
operation)
0°C ... +55°C
Permissible ambient temperature range (during
storage)
25°C ... +85°C
Permissible relative humidity
95%, no condensation
Dimensions (W x H x D)
approx. 15 mm x 100 mm x 70 mm (width aligned: 12
mm)
on 35 mm mounting rail conforms to EN 60715
Vibration/shock resistance
conforms to EN 6006826/EN 60068227
EMC resistance burst/ESD
conforms to EN 6100062/EN 6100064
Protect. class
IP 20
Installation pos.
variable, see chapter "Mounting of Passive Terminals
[
Approval
CE
ATEX [
LEDs und Anschlussbelegung EL9570
LED
Color
Meaning
Overload
green
off
No error
on
Overload, energy will be absorbed in the connected
ballast resistor
EL9xxx
50
Version 3.1