beautypg.com

3 seconds ups, 1 s-ups: capacitive one-second ups, 3seconds ups – BECKHOFF CX51x0 User Manual

Page 19: 1 s­ups: capacitive one­second ups

background image

Seconds UPS

3

Seconds UPS

3.1

S­UPS: capacitive one­second UPS

The CX51x0 family features a built­in capacitive one­second UPS. It ensures a safe storage of the persistent
application data on the Compact Flash card.

Up to 1 MB of persistent data can be saved. The UPS can be switched on and off via the BIOS. Under the
menu:

Advanced ­> Power Controller Options

the parameter of the S­UPS are displayed and can be modified, if required.

Aptio Setup Utility ­ Copyright (C) American Megatrends, Inc.

Bootloader version

1.00­23

WatchDogTimer mode

Firmware version

1.00­77

Mainboard serial no

120003414250178

Mainboard Prod. date (Week.Year) 44.14

Mainboard BootCount

4711

Mainboard operation time

1224min (20h)

Voltage (Min/Max)

5.00V / 5.20V

Temperature (Min/Max)

15°C / 63°C

USB­Port voltage

[Off in S3­5]

WatchDogTimerMode

[Compatibility mode]

1­second Uninterruptable Power Supply (SUPS)

→ ←: Select Screen
↑ ↓: Select Item
Enter: Select
+/­: Change Options
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Quit

SUPS Enable

[Enable]

Hold Usb

[Enable]

Delay

0

SUPS Firmware version

1.09

Current Power source

On Line

Battery load level

100%

Powerfail counter

42

Version 2.17.1246. Copyright (C) 2014 American Megatrends, Inc.

SUPS Enable
Options: Enable / Disable
Switches the SUPS on or off.

CX51x0

19

Version 1.0