beautypg.com

7 label distance (lpit), Check setting, Als 380 – Avery Dennison ALS 380 User Manual

Page 61

background image

59

4

O

PERATION

4.4 S

ETTINGS

IN

THE

EXTENDED

MENU

ALS

380

4.4.7

Label distance

(LPIT)

The label distance is defined as [62]:
Label distance = label length + gap

The shape of the labels or reflective surfaces can
cause a false signal to be sent from the label stop sen-
sor. In such a case, the label distance must be manual-
ly set.

In the extended menu:

Call up the LPIT function.

Set the desired distance.

– Settings are possible in 0.1 mm steps:

Minimum: 5 mm
Maximum: 500 mm

Confirm the value using the ENTER key and exit the
function.

Press the FEED key to test the setting.

– A single label is dispensed.

Check setting

Press the FEED key.

If the setting is correct:
– A single label is dispensed at a constant dispensing

speed. The label completely separates from the
backing material and no wrinkling occurs.

If the setting value for LPIT is too large:
– 2 labels are dispensed.

If the setting value for LPIT is too small:
– A single label is dispensed.
– Because the value for LPIT is too small, the control

unit prematurely anticipates a signal from the label
stop sensor. The missing signal triggers automatic
label compensation. This error is indicated if:

– The dispensing speed is excessively fast at

the trailing edge of the label.

– If a printer is connected, the device will print

more than once.

[62] A Label distance

B Label length
C Gap

A

B

C