Avalon Firestyles D-V-1995 User Manual
Page 5
![background image](https://www.manualsdir.com/files/772741/content/doc005.png)
F
EATURES AND
S
PECIFICATIONS
P
AGE
5
Installation Options:
¥
Residential or Mobile Home
¥
Straight or Corner Placement
¥
Bedroom Approved
¥
Alcove Approved
¥
Vertical or Horizontal Vent
¥
Approved for use in homes of
unusually tight construction
Features:
¥
Works During Power Outages (standing pilot)
¥
High Efficiency; 81.5% Natural Gas, 83.3% LP (Steady State)
¥
Optional Thermostat or Remote Control
¥
Realistic "Wood Fire" Look
¥
Convenient Operating Controls
¥
Variable-Rate Heat Output
¥
Quiet Blower for Effective Heat Distribution
¥
Low Maintenance
Heating Specifications:
Natural Gas
LP (Propane)
Approximate Heating Capacity (in square feet)*
600 - 1600
600 - 1600
High Burn Input Rate (In BTU's)
31,000
31,000
Low Burn Input Rate (In BTU's)
18,000
17,000
Efficiency**
81.5%
83.3%
AFUE (Annual Fuel Utilization Efficiency)
72.6%
74.2%
*
Heating capacity will vary with the home's floor plan and insulation, natural gas or Propane BTU rating, and outside temperature.
**
Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent of installed system.
To measure the net BTU's, multiply the BTU input by the efficiency percentage (81.5% for natural gas, 83.3% for LP).
Dimensions
4-1/2"
20"
24-1/2"
31-1/4"
2-3/4"
Fuel:
The stove is designed either for natural gas or for propane. Check
the sticker on the top of the gas control valve.
Emissions:
This unit has passed the ANSI emission standards for vented room
stoves as tested by Warnock Hersey, LTD.
Electrical Specifications:
115 Volts, 1.3 Amps, 60 Hz (150 watts on high)