beautypg.com

Avalon Firestyles D-V-1995 User Manual

Page 5

background image

F

EATURES AND

S

PECIFICATIONS

P

AGE

5

Installation Options:

¥

Residential or Mobile Home

¥

Straight or Corner Placement

¥

Bedroom Approved

¥

Alcove Approved

¥

Vertical or Horizontal Vent

¥

Approved for use in homes of
unusually tight construction

Features:

¥

Works During Power Outages (standing pilot)

¥

High Efficiency; 81.5% Natural Gas, 83.3% LP (Steady State)

¥

Optional Thermostat or Remote Control

¥

Realistic "Wood Fire" Look

¥

Convenient Operating Controls

¥

Variable-Rate Heat Output

¥

Quiet Blower for Effective Heat Distribution

¥

Low Maintenance

Heating Specifications:

Natural Gas

LP (Propane)

Approximate Heating Capacity (in square feet)*

600 - 1600

600 - 1600

High Burn Input Rate (In BTU's)

31,000

31,000

Low Burn Input Rate (In BTU's)

18,000

17,000

Efficiency**

81.5%

83.3%

AFUE (Annual Fuel Utilization Efficiency)

72.6%

74.2%

*

Heating capacity will vary with the home's floor plan and insulation, natural gas or Propane BTU rating, and outside temperature.

**

Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent of installed system.
To measure the net BTU's, multiply the BTU input by the efficiency percentage (81.5% for natural gas, 83.3% for LP).

Dimensions

4-1/2"

20"

24-1/2"

31-1/4"

2-3/4"

Fuel:

The stove is designed either for natural gas or for propane. Check
the sticker on the top of the gas control valve.

Emissions:

This unit has passed the ANSI emission standards for vented room
stoves as tested by Warnock Hersey, LTD.

Electrical Specifications:

115 Volts, 1.3 Amps, 60 Hz (150 watts on high)