Perating, Eater before you begin, Location of controls - see explanation below – Avalon Firestyles D-V-1995 User Manual
Page 24
![background image](https://www.manualsdir.com/files/772741/content/doc024.png)
P
AGE
24
O
PERATING
Y
OUR
H
EATER
Before You Begin
!
Read this entire manual before you use your new stove (especially the section "Safety
Precautions" on pages 2 & 3). Failure to follow the instructions may result in property
damage, bodily injury, or even death.
Location of Controls - See explanation below
Grasp the control cover with both hands and
lift it up and off the hooks that hold it in place.
Place it on a non-scratching surface.
Gas
Control
Valve
PILOT ADJ
VENT
T
O
L
PI
ON
OFF
HI
LO
Gas Control
Knob
Flame Adjust
Knob
TO ACCESS THE CONTROLS:
Blower Knob
BLOWER
LO
OFF
HI
PILOT
IGNITER
Pilot Igniter
ON/OFF Switch
The on/off switch is located on the
rear panel.
The Pilot Flame can be
found below the front log
on the left side.
OF
F
ON
On/Off Switch
This control is used to turn the main burner on and off.
Gas Control Knob
This knob is used to control gas to the stove and for starting the pilot. There
are three positions, ON, OFF, & PILOT. The pointer directly below the knob
indicates the position this knob is in.
Flame Adjust Knob
This knob controls the flame height from low ("LO") to high ("HI"). The
pointer to the upper right of the knob points to the position this knob is in.
Pilot Igniter
The pilot igniter is used only to start the pilot. When pressed, it sends an
electrical charge to the pilot assembly. This creates a blue spark directly next
to the pilot, igniting the pilot flame.
Blower Knob
This knob controls the speed of the internal convection blower that pushes the
heated air into the room.
?
If using a remote control or thermostat, the On/Off Switch must be left "ON". Turning the On/Off
Switch "OFF" will keep the stove off always.