beautypg.com

Table 5-13, Serial port console redirection, Bios – Artesyn NITX-300-ET-DVI Installation and Use (August 2014) User Manual

Page 68

background image

BIOS

NITX-300-ET-DVI Installation and Use (6806800N97B)

68

Table 5-13 Serial Port Console Redirection

Field

Description

COM0(Pci Bus2,Dev10,Func1)

Console Redirection

Console Redirection Enable or Disable. Default is Disabled.

Console Redirection Settings

See

Table 5-13 on page 68

COM1(Pci Bus 2,Dev 10,Func2)

Console Redirection

Console Redirection Enable or Disable. Default is Disabled.

Console Redirection Settings

See later description

COM2(Pci Bus 2,Dev 10,Func3)

Console Redirection

Console Redirection Enable or Disable. Default is Disabled.

Console Redirection Settings

See later description

COM3(Pci Bus 2,Dev 10,Func4)

Console Redirection

Console Redirection Enable or Disable. Default is Disabled.

Console Redirection Settings

See

Table 5-13 on page 68

Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS)

Console Redirection

Console Redirection Enable or Disable. Default is Disabled.

Out-of-Band Mgmt Port

Microsoft Windows Emergency Management Serivces (EMS)
allows for remote management of a Windows Server OS through a
serial port. Items: COM0, COM1, COM2, COM3. Default is
COM0(Pci Bus2, Dev10, Func1)

Data Bits

8

Parity

None

Stop Bits

1

Terminal Type

VT-UTF8 is the preferred terminal type for out-of-band
management. The next best choice is VT100+ and then VT100.
See above, in Console Redirection Settings page, for more Help
with Terminal Type/Emulation. Items: VT100, VT100+, VT-UTF8,
ANSI. Default is VT-UTF8.