beautypg.com

1 environmental requirements, Table 4-1, Environmental requirements – Artesyn Centellis 2000 User Card-10GE Installation and Use (May 2014) User Manual

Page 36: Board exchange

background image

Board Exchange

Centellis 2000 User Card-10GE Installation and Use (6806800H33C)

36

4.2.1.1

Environmental Requirements

You must make sure that the board when operated in your particular system configuration
meets the environmental requirements specified below.

Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.

Board Damage
High humidity and condensation on the board surface causes short circuits.
Do not operate the board outside the specified environmental limits. Make sure the board
is completely dry and there is no moisture on any surface before applying power.

Table 4-1 Environmental Requirements

Feature

Operating

Non-Operating (packed state)

Temperature

+5 ºC (+41 °F) to +40 ºC (+104 °F)
(normal operation) according to NEBS
Standard GR-63-CORE
-5 °C (+23 °F) to + 55 °C (+131 °F)
(exceptional operation) according to
NEBS Standard GR-63-CORE

-40 ºC (-40 °F) to +85 ºC (+185 °F)

Temp. change

+/- 0.25 ºC/min according to NEBS
Standard GR-63-CORE

+/- 0.25 ºC/min

Relative humidity 5% to 90% non-condensing according

to Artesyn internal environmental
requirements

5% to 95% non-condensing according to
Artesyn internal environmental
requirements

Vibration (tested
in target
platform)

0.1 g from 5 to 100 Hz and back to 5 Hz
at a rate of 0.1 octave/minute.

5-20 Hz at 0.01 g

2

/Hz

20-200 Hz at -3.0 dB/octave
Random 5-20 Hz at 1 m

2

/Sec

3

Random 20-200 Hz at -3 dB/octave