beautypg.com

Connecting subscriber wiring, Connecting subscriber wiring 17 – ARRIS TM508 Installation Guide User Manual

Page 27

background image

17

TM508/TM512 Installation Guide Release 5 Standard 1.2 Mar 2007

5

Tighten the screws to firmly hold the punch-down block against the
mounting surface.

Connecting
Subscriber Wiring

Follow these steps to connect subscriber wiring to the punch-down
block. Consult the following diagram while making connections.

1

Identify the tip-ring wire pair that should be associated with the
Telephony Modem line that you are connecting.

2

Route the wire pair to reach the right side of the punch-down block.

3

Using the punch tool, punch the tip wire into the first of the two
connections for the line, and the ring wire into the second connec-
tion. It is not necessary to strip the wires before punching.

4

Install two bridging clips across the tip and ring lines to enable tele-
phone service (clips for line 1 are shown above).

5

Repeat steps 1 through 4 for each line to install.

6

Close the punch-down block cover after connecting all lines.

Bridging Clips

(required to

enable service)

Network side

Subscriber side

Line 1 – Tip

Line 1 – Ring

Line 1 – Tip

Line 1 – Ring