Programming Events (Keypad Interface)
Wired Signal Circuit Option
The SiteSync IQ System Controller contains 6 integrated signal relays. When configured, the Wired Signal Circuit Option allows the System
Controller to be used for operating bells, tone generators, lighting circuits and other electrical equipment. Events may also be configured to
trigger countdown digital clocks that are equipped with the Countdown adder (SQAxxxxxxC[1-6]).
n
Note: System Controllers with the Ethernet option can also be programmed via the Remote Connect web interface (see page 33).
Definitions:
An
Event is programmed into the System Controller with time and date information, as well as a duration or a start/stop command. For
example, Event 0001 may be programmed to execute every Monday, Wednesday and Friday at 10:00 am for 3 seconds. Each event is
assigned to a
Schedule. The SiteSync IQ System Controller can store up to 9,999 events. The event duration is programmable from 1 to 9
seconds and also allows for ON or OFF commands. Normal events are recurring weekday events. A
Special Event contains date information
that is not specific to weekdays. For example, you can set a special event for the 4th day of every month, the 4th day of every January or
the 4th day of January in a specific year. You can also set a special event for every Thursday in January or every Thursday in a specific year.
A
Schedule Change Event is entered in the same manner as a Special Event. A schedule change event allows you to change from one
schedule to another. This may be useful for changing from a normal schedule to a holiday schedule.
A
Schedule is a group of events. For example, a school might program Schedule 01 with 4 events for their morning Elementary recess
schedule. The SiteSync IQ System Controller allows for 99 unique schedules, with any number of events in each (up to a maximum total of
9,999 events). Schedules, with groups of events, are assigned to
Circuits.
A
Circuit is defined as one of the 6 relay outputs on the SiteSync IQ System Controller. Each circuit can be assigned one schedule at a time.
For example, Schedule 01 with 4 events might be assigned to Circuit 1 and Schedule 03 with 10 events might be assigned to Circuit 2.
u
Programming New Events
a. Press:
P2
, enter User Lock using the keypad and press
O
to
enter the Event Menu.
b. Press:
1
to add an event.
c. Select the number of the schedule for the new event and press
O
.
d. If any events have already been assigned to the selected schedule, the
days and start time for the first event are displayed. Use the
>
key to
move to the New Event screen. Press
O
to display the Select
Weekdays screen.
n
Note: Press
<
on the first event to view the last event. Press
>
to move
to the New Event Screen.
e. To program event days, press
1
through
7
keys to add or remove
days individually, or
Press
8
to add weekdays (shown),
9
to add weekends, or
Press
0
for special events or schedule change events. This allows
events to be defined by date(s). Please reference Sections 3
(Programming Special Events) and 4 (Programming Schedule Change
Events) for details.
Press
O
to accept the assigned days.
Select Weekdays:
8=M-F
MTWTF
9=S+S Key 1234567
0=Spec/Sch
OK=Accpt
Event Menu
Sch=10 Event=0000
2014-02-10 12:04 AM
Event Menu
Choose Schedule
Sch=01 Select 1-99
OK=Accept
Event Menu
View Events by:
1=Schedule/Event
2=Date/Time
3=WKDY
1e
1d
1c
1a and b
Glossary
Appendix
Troubleshooting
Clock
Installation
System Contr
oller
Installation
Intr
oduction
v
Programming Recurring Events by Weekday
For a non-special event, this brings up the Event Time screen.
To program start time:
a. Use the number keys to enter the hour and minute. Press
<
for AM or
>
for PM. Press
O
to accept the event start time.
The Event Duration screen appears. To program event duration (1-9 seconds):
b. Press any number
1-9
to specify duration, or
Press
0
to use the default duration(s) for the circuit(s) assigned to the
schedule, or
Press
>
to latch assigned circuits on until a later event turns them off, or
Press
<
to turn off assigned circuits that were previously turned on.
Press
O
to accept event duration.
Event menu
Duration 0=Default
2 Sec (1-9, < or >)
Off=< On=> OK=Set
Event menu
Select event time:
Evt Time: 12:00 AM
MTWTF OK=Acpt
2b
2a
MON MAR 10 2014
10:38:06 AM USCT
American Time
Status=AUTO ETH=Y