System controller setup wizard – American Time SiteSync IQ User Manual
Page 13

13
© American Time
SiteSync IQ Installation Manual
System Controller
Setup Wizard
MON MAR 10 2014
10:38:06 AM USCT
American Time
Status=AUTO CDMA=S
Glossary
Appendix
Troubleshooting
Clock
Installation
System Contr
oller
Installation
Intr
oduction
Setup Wizard
Successfully Completed
1 0 : 3 8
:06
MAR 10 2014
TX
MON MAR 10 2014
10:38:06 AM USCT
American Time
Circts=Auto
TX
Set Menu
Ethernet Sync
Failed
Set Menu
Ethernet Sync
Successful
Set Menu
Time Sync Option is
Available: Ethernet
8=Sync now
OK=Set
Comm Menu
Enter Port Number
for web access: 80
OK=Done
25
26a-large text mode
26b-small text mode
24b (example)
24a (example)
24 (example)
23
21
22
Programming Procedure
(cont)
To confirm proper set up, sync each option.
Press
8
to sync.
• a. If successful "Sync Successful" will display.
• b. If not successful, "Sync Failed" will display.
Refer to the troubleshooting guide.
• Press
O
to exit the Sync Now function.
Screen 25 will be displayed when the Setup Wizard has been
completed. You will no longer be prompted on power-up for the setup
information.
The System Controller should now show the correct time and date on
its display screen.
• a. Verify the unit is transmitting. TX should display for about 3
seconds every 30 seconds (approximately the top and bottom of
every minute)
on the screen below the seconds (large text
mode)
or in the
bottom right corner of the screen (small
text mode).
• b. For systems with an external transmitter, verify the DATA and
PTT lights turn on when TX is displayed as described above.
Your System Controller is now set up for proper operation. You can continue
to the other sections of this manual for further information on other features.
If you have any questions or problems that cannot be resolved by following
the steps in the Troubleshooting Guide, please contact Technical Support at
American Time (800-328-8996).
24
25
26
The unit will prompt you to enter the Port Number. This is
remote web access and should be set to 0080.
• Port Number:
0080
• Press
O
to accept the default (80) set at the factory
23
Use the keypad to enter the Time Server address. Enter preceding zeros as
necessary.
• Time Server Address:
• Press
O
OR Press
O
to accept the default set at the factory from the list of known
good Internet Time Servers in Appendix A.
Use the keypad to enter the Alternate Time Server address. Enter preceding
zeros as necessary.
• Alt. Time Server Address:
• Press
O
OR Press
O
to accept the default set at the factory from the list of known
good Internet Time Servers in Appendix A.
21
22
Comm Menu
Time Server Address
131.107.013.100
<=Bksp
OK=Done
Comm Menu
Alt Time Srvr Addr
173.014.055.009
<=Bksp
Ok=Done