Troubleshooting AllSync IQ Master

CAUTION: Warranty may be voided if LCD/Keypad cover is removed prior to contacting Technical Support at American Time
at the number listed below.

If you have any of these problems, follow the appropriate steps:
1. AllSync IQ master appears off (LCD dark) when power is connected:

• Check power switch located on left side of the AllSync IQ master. Switch should show red when on.

• Disconnect power and remove wiring compartment cover. Check fuse and replace if necessary.

• To test power input fuse, disconnect/lockout power and remove connector to power switch from J23 located above

and left of the power input fuse. Check continuity between the H screw terminal and bottom J23 pin.

2. Incorrect time is displayed by AllSync IQ master after loss of power:

• Backup battery may be dead. Contact Technical Support at American Time at the number listed below.

CAUTION: Danger of explosion if battery is incorrectly placed. Replace only with the same or equivalent type.

3. Power outage during Daylight Saving Time correction:

• If there is a power outage during the correction period for Daylight Saving Time, the secondary clocks might not

correct. In this event, wait for the next 12 hour correction .

4. Signal circuits not responding to programmed events:

• Refer to Wired Signal Circuit Troubleshooting Guide.

5. Unable to synchronize with Ethernet Time Source:

• Refer to the Ethernet Troubleshooting Guide.

6. Lost or forgotten User Lock:

• Contact American Time Technical Support at the number listed below.

7. AllSync IQ Master locks up or display goes blank:

• Remove power from the unit by switching the Power Input switch off, wait 5 seconds, then turn the unit back on.

NO

H

N

COM

NC

CLOCK 1

NO

COM

NC

CLOCK 2

NO

COM

BELL 1

NO

COM

BELL 2

NO

COM

BELL 3

NO

COM

BELL 4

NO

COM

BELL 5

NO

COM

BELL 6

Circuit Protection

Switches

POWER 120 VAC

50/60 Hz

CLOCK RELAY

BELL RELAY

Power Input

Fuse

1:49

FRI OCT 3 2014

:45

AM

American Time 

800-328-8996

If the problem cannot be resolved after following these steps, please call Technical Support at American Time at

800-328-8996.