Wired Signal Circuit Option
Programming Signal Circuits (Keypad Interface)
Optional signal relays for controlling signal or lighting circuits must be assigned to schedules of events for automatic control. Multiple
circuits can be assigned to one schedule, but each signal circuit can be assigned to only one schedule.
Each signal circuit is also programmed with a default event duration. This allows different signal circuits assigned to the same schedule to
be activated for different lengths of time for the same event. For example, a school may have circuit 1 connected to the elementary bells
and wish to ring those for 3 seconds. It may have circuit 2 connected to the middle school bells and wish to ring those for 5 seconds.
The same events can be assigned to a single schedule but will have different durations on different circuits when using circuit duration
defaults. This default duration can be overridden by the duration specified for an event (described in the Programming Events section).
n
Note: AllSync IQ masters with the Ethernet option can also be programmed via the Remote Connect web interface (see page 25).
Signal Circuit Menu
u
Setting Signal Circuit Schedule and Duration
a. Press
P3
. Enter User Lock (unless User Lock is disabled) and
Press
O
(unless User Lock is disabled) to enter Circuit Menu.
b. Press
1
to select the Signal Circuit Schedule Assignment screen. The
current schedule assignments for all circuits are shown. To change the
schedule assignment for a circuit, press the number of the circuit (i.e.
1
).
c. Assign a schedule to this circuit by pressing the or buttons until the
correct schedule is displayed. (Pressing 0 disables the circuit) Press
O
to
accept.
This returns you to the Signal Circuit Schedule Assignment screen (
b).
Press
B
.
Press
2
to bring up the Duration screen.
Circuit Menu
Cir:01 Choose Sch
Sch: 01
00=Special
OK=Accept
Circuit Menu
Select Circuit:
Cir
1 2 3 4 5 6
Sch 01 01 02 02 03 03
Circuit Menu
View Circuits for:
1=Schedule 3=On/Off
2=Duration Prog=Exit
1c
1b
1a
From Program
Menu
User Lock
Enable
Circuits
Select
Circuit
Select
Duration
1-9, < or >
Select
Schedule
Select
Circuit
Exit to Main
Screen
View Circuits
1=Schedule 3=On/Off
2=Duration
3
3
2
1-6
1-6
1
OK
PROG
OK
OK
OK
n
Note: To return to the View
Circuits screen from any of these
screens, press the
B button.