Wired Clock Circuit Option

Wired Clock Circuit Installation

To install wired clock circuits:
1. Disconnect and lock out power to the AllSync IQ Master and any circuit wiring.
2. Remove the terminal block cover from the AllSync IQ.
a. Remove screw from each side of the cover.
b. Lift the cover up off the unit.
3. Route signal circuit wires into the wiring compartment of the AllSync IQ.

a. Remove knockout(s).

b. Use copper conductors only.
c. Use strain relief connector fittings in the knockout holes to secure the wires.
d. Route the wires into the wiring compartment, leaving enough slack to make all connections to the relay terminals.
4. Connect clock wires to the circuit relay terminals

NO

H

N

COM

NC

CLOCK 1

NO

COM

NC

CLOCK 2

NO

COM

BELL 1

NO

COM

BELL 2

NO

COM

BELL 3

NO

COM

BELL 4

NO

COM

BELL 5

NO

COM

BELL 6

Clock Circuit Terminals

Surge Supression

ON/OFF Switches

Clock Circuit Fuses

See Appendix H on Page 50 for Clock Circuit Wiring Diagram