Jumper and switch settings, Motor type selection (j4), Vbus selection: 24 v (internal) or external (j9) – Zilog ZUSBOPTS User Manual
Page 29: Table 15, Motor type jumper, Selection: 24 v (internal) or external (j9)

UM026203-0115
MultiMotor Series Development Board
MultiMotor Series Development Kit
User Manual
22
Do not use bus voltages higher than 24V DC with the Linix motor supplied with this kit.
Jumper and Switch Settings
This section describes the jumper and switch settings.
Motor Type Selection (J4)
Under standard conditions, this Motor Type Selection jumper J4 should be in the BLDC
position (2-3). If you are working with an AC induction motor (ACIM), this jumper
should be changed to position 1-2 to make the tachometer signal from the ACIM available
to the MCU; see Table 15.
V
BUS
Selection: 24 V (Internal) or External (J9)
Under standard conditions, the jumper should be in the 24 V (Internal) position (2-3). If
you are working with a motor that requires more than 24 V DC bus voltage, or if the motor
is rated for more than 30 W, power must be supplied through J7; this jumper must be in the
External position. Refer to Table 16 for details.
The MultiMotor Series Development Board has been designed to be used with motors
rated for current and power specifications up to 48 V DC and 30 W. Zilog recommends
that this hardware not be used with motors that exceed these specifications.
Table 15. Motor Type Jumper
Motor Type
Jumper Location
1-2
2-3
BLDC
X
ACIM
X
Table 16. V
BUS
Selection Jumper
Jumper
Position
Jumper Location
1-2
2-3
External
X
24 V (Internal)
X
Caution: