beautypg.com

Digital output – NEXCOM VTC 7100-D1K User Manual

Page 90

background image

Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.

76

Appendix D: Signal Connection of DI/DO

VTC 71-D Series User Manual

Digital Output

CN18 connector for GPO signal (digital signal output)
The CN18 has 4 digital output channels. Each channel can accept 0~30Vdc
voltage. And it is able to drive 250mA current for low level. The signal
connection of CN18 support two connected methods for output signal type.

The output signal has two states, one is low level (driven to 0V from GPO
signal) other is open (high voltage is provided from external device).

G_OUT1

G_OUT2

G_OUT3

G_OUT4

VCC5

330E

0603

330E

0603

330E

0603

Z12003

Z12004

Z12005

Z12006

330E

0603

SW4

DIP SW 2X4

SW4

DIP SW 2X4

1

2

3

4

6

5

7

8

330E

0603

330E

0603

330E

0603

330E

0603

GPO (SW4)

On

Pull up VCC5

Don’t Care

Off

Wet Contact (default)
The SW4 needs to switch to “ON” state. The GPO signal will have a pull up
resistor to 5V internally when you switch “SW1” to “ON” state. The output
signal has two states, one is low level (driven to 0V from GPO signal ) other
is high level (driven to 5V from GPO signal).

The figure below shows how to connect an external input source to one of
the isolated output channel.

G_OUT1

G_OUT2

G_OUT3

G_OUT4

G_OUT4

G_OUT3

G_OUT2

G_OUT1

VCC5

GPO1

GPO0

GPO2

GPO3

330E

0603

330E

0603

330E

0603

330E

0603

EMB17A03G

EMB17A03G

8

7

6

5

1

2

3

4

EMB17A03G

EMB17A03G

8

7

6

5

1

2

3

4

330E

0603

330E

0603

330E

0603

330E

0603

This manual is related to the following products: