Delay timer setting – NEXCOM NViS 3542 User Manual
Page 158
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
121
NViS 3540/3540H/3540P4/3540P8 and NViS 3542/3542H/3542P4/3542P8 User Manual
Appendix F: PoE Device Setup
Appendix I: Power On/Off Delay Timer Setting
(NISKIG120)
Delay Timer Setting
Power On Delay Timer
SW2
DIP Switch 1
Function Setting
Note
0
0=OFF
Disable (default 3 seconds)
Default
1
1=ON
Enable (DIP Switch 3,4,5)
Power Off Delay Timer
SW2
DIP Switch 2
Function Setting
Note
0
0=OFF
Disable (default 0 second)
Default
1
1=ON
Enable (DIP Switch 6,7,8)
DIP Switch 3, 4, 5
POWER ON Delay Timer Select
000
10sec
100
30sec
010
1min
110
5min
001
10min
101
15min
011
30min
111
1hour
DIP Switch 6, 7, 8
POWER OFF Delay Timer Select
000
20sec
100
1min
010
5min
110
10min
001
30min
101
1hour
011
6hour
111
18hour