Appendix F: PoE Device Setup

Appendix G: Voltage Low Shut-down Setting
(NISKIG120)

Voltage Low Shut-down Setting (12V DC Input)

Voltage Low Shut-down Setting (24V DC Input)

SW1

DIP Switch 1

DIP Switch 2

Start-Up

Shut-Down

Note

00

0=OFF

0=OFF

11.5V

10.5V

Default

01

0=OFF

1=ON

12V

11V

10

1=ON

0=OFF

12.5V

11V

11

1=ON

1=ON

12.5V

11.5V

SW1

DIP Switch 1

DIP Switch 2

Start-Up

Shut-Down

Note

00

0=OFF

0=OFF

23V

21V

Default

01

0=OFF

1=ON

24V

22V

10

1=ON

0=OFF

25V

22V

11

1=ON

1=ON

25V

23V