beautypg.com

Power consumption measurement – NEXCOM NViS 3542 User Manual

Page 132

background image

Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.

95

NViS 3540/3540H/3540P4/3540P8 and NViS 3542/3542H/3542P4/3542P8 User Manual

Appendix A: Power Consumption

Power Consumption Measurement

Purpose
The purpose of the power consumption test is to verify the power dissipa-
tion of the system and the load of the power supply.

Test Equipment
PROVA CM-07 AC/DC CLAMP METER

Device Under Test
DUT: Sys #1 / Sys #2

Test Procedure
1. Power up the DUT and then boot Windows XP.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Run the Intel Kpower program.
5. Run the LAN Packet Counter and Receive program.

Test Data

Sys #1

Sys #2

+19V

+19V

Full-Loading Mode

2.97A

2.43A

Total

56.43W

46.17W

Standby Mode

1.025A

0.99A

Total

19.475W

18.81W